{"title":"30% TPL Stabilizers","description":"","products":[{"product_id":"tpl-series-three-phase-stabilizer-servo-liner-30-100kva","title":"TPL Series Three Phase Stabilizer Servo Liner 30% - 100KVA","description":"\u003cstyle\u003e\n\n\/* ==========================\n   TPL PRODUCT STYLE (100 KVA VERSION)\n========================== *\/\n\n.tpl-description{\n    font-family: inherit;\n    line-height:1.7;\n    color:#1f2937;\n}\n\n\/* ===== FEATURES GRID (CARDS) ===== *\/\n\n.tpl-features-table{\n    width:100%;\n    border-collapse:separate;\n    border-spacing:0 12px;\n    margin:30px 0;\n}\n\n.tpl-features-table td{\n    background:#EEF4FB;\n    border:1px solid rgba(0,82,157,.10);\n    border-radius:14px;\n    padding:16px;\n    vertical-align:top;\n    width:50%;\n}\n\n.tpl-features-table td p{\n    margin:0;\n    font-size:14px;\n    line-height:1.6;\n}\n\n.tpl-features-table td span{\n    font-weight:600;\n    color:#00529D;\n}\n\n\/* ===== SPEC TABLE ===== *\/\n\n.tpl-specs-table{\n    width:100%;\n    border-collapse:collapse;\n    border-radius:18px;\n    overflow:hidden;\n    margin-top:25px;\n}\n\n.tpl-specs-table thead th{\n    background:#00529D;\n    color:#fff;\n    padding:16px;\n    text-align:left;\n    font-size:15px;\n    font-weight:600;\n}\n\n.tpl-specs-table tbody tr:nth-child(odd){\n    background:#EEF4FB;\n}\n\n.tpl-specs-table tbody tr:nth-child(even){\n    background:#ffffff;\n}\n\n.tpl-specs-table td{\n    padding:14px;\n    border-bottom:1px solid rgba(0,82,157,.08);\n    font-size:14px;\n}\n\n.tpl-specs-table td:first-child{\n    font-weight:600;\n    color:#00529D;\n    width:35%;\n}\n\n.tpl-specs-table tr:hover{\n    background:rgba(0,82,157,.05);\n}\n\n\/* ===== MOBILE ===== *\/\n\n@media(max-width:768px){\n    .tpl-features-table td{\n        display:block;\n        width:100%;\n        margin-bottom:12px;\n    }\n}\n\n\u003c\/style\u003e\n\n\u003cdiv class=\"tpl-description\"\u003e\n\n\u003c!-- HERO --\u003e\n\u003cp\u003e\nThe TPL 30% — 100 KVA handles 216.5 A with a ±30% input tolerance, designed for environments where grid voltage can drop to 266V or surge above 490V. Its wide correction window ensures stable output for sensitive equipment, including medical devices, VFDs, and precision systems. Built with a compact 407×1650×930 mm cabinet and a weight of 830 KG, it is ideal for indoor installation in clean electrical rooms and light industrial environments.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2\u003eOutstanding Features\u003c\/h2\u003e\n\n\u003ctable class=\"tpl-features-table\"\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 100 KVA \/ 216.5 A\u003c\/span\u003e\u003cbr\u003ewidest correction window in the range\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Class H insulation\u003c\/span\u003e\u003cbr\u003econtinuous full-load operation\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Medical \u0026amp; industrial protection\u003c\/span\u003e\u003cbr\u003eVFDs, precision \u0026amp; sensitive loads\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Modbus communication\u003c\/span\u003e\u003cbr\u003eBMS \/ monitoring integration\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 266V–494V range\u003c\/span\u003e\u003cbr\u003estable output during severe dips\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 150% overload\u003c\/span\u003e\u003cbr\u003e1 min motor startup support\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 407mm compact cabinet\u003c\/span\u003e\u003cbr\u003eideal for clinics \u0026amp; electrical rooms\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Roller brush system\u003c\/span\u003e\u003cbr\u003elow maintenance operation\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ IP23 protection\u003c\/span\u003e\u003cbr\u003eclean \u0026amp; light industrial use\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ High stability design\u003c\/span\u003e\u003cbr\u003efor weak grid environments\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable class=\"tpl-specs-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e100 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e216.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage tolerance\u003c\/td\u003e\n\u003ctd\u003e+30% to -30% (266V – 494V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% to ±1% (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrection speed\u003c\/td\u003e\n\u003ctd\u003e20 ms \/ volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad unbalance\u003c\/td\u003e\n\u003ctd\u003eUp to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation class\u003c\/td\u003e\n\u003ctd\u003eClass H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP23 — Indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Air + Forced Fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e407 × 1650 × 930 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e830 KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"TPL Stabilizers","offers":[{"title":"Default Title","offer_id":52015560229147,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/0255\/6699\/files\/3Ph.jpg?v=1775385772"},{"product_id":"tpl-series-three-phase-stabilizer-servo-liner-30-150kva","title":"TPL Series Three Phase Stabilizer Servo Liner 30% - 150KVA","description":"\u003cstyle\u003e\n\n\/* ==========================\n   TPL PRODUCT STYLE (150 KVA VERSION)\n========================== *\/\n\n.tpl-description{\n    font-family: inherit;\n    line-height:1.7;\n    color:#1f2937;\n}\n\n\/* ===== FEATURES GRID (CARDS) ===== *\/\n\n.tpl-features-table{\n    width:100%;\n    border-collapse:separate;\n    border-spacing:0 12px;\n    margin:30px 0;\n}\n\n.tpl-features-table td{\n    background:#EEF4FB;\n    border:1px solid rgba(0,82,157,.10);\n    border-radius:14px;\n    padding:16px;\n    vertical-align:top;\n    width:50%;\n}\n\n.tpl-features-table td p{\n    margin:0;\n    font-size:14px;\n    line-height:1.6;\n}\n\n.tpl-features-table td span{\n    font-weight:600;\n    color:#00529D;\n}\n\n\/* ===== SPEC TABLE ===== *\/\n\n.tpl-specs-table{\n    width:100%;\n    border-collapse:collapse;\n    border-radius:18px;\n    overflow:hidden;\n    margin-top:25px;\n}\n\n.tpl-specs-table thead th{\n    background:#00529D;\n    color:#fff;\n    padding:16px;\n    text-align:left;\n    font-size:15px;\n    font-weight:600;\n}\n\n.tpl-specs-table tbody tr:nth-child(odd){\n    background:#EEF4FB;\n}\n\n.tpl-specs-table tbody tr:nth-child(even){\n    background:#ffffff;\n}\n\n.tpl-specs-table td{\n    padding:14px;\n    border-bottom:1px solid rgba(0,82,157,.08);\n    font-size:14px;\n}\n\n.tpl-specs-table td:first-child{\n    font-weight:600;\n    color:#00529D;\n    width:35%;\n}\n\n.tpl-specs-table tr:hover{\n    background:rgba(0,82,157,.05);\n}\n\n\/* ===== MOBILE ===== *\/\n\n@media(max-width:768px){\n    .tpl-features-table td{\n        display:block;\n        width:100%;\n        margin-bottom:12px;\n    }\n}\n\n\u003c\/style\u003e\n\n\u003cdiv class=\"tpl-description\"\u003e\n\n\u003c!-- HERO --\u003e\n\u003cp\u003e\nThe TPL 30% — 150 KVA steps into the wider 515mm cabinet format at 288.6 A, designed for medium facilities in regions where grid voltage is chronically unstable. The unit’s columnar voltage regulator design provides higher power density, allowing 150 KVA of stable output from a compact enclosure. With a weight of 1110 KG and dimensions of 515×1700×1127 mm, it is built for reliable installation in demanding environments.\n\u003c\/p\u003e\n\n\u003c!-- FEATURES --\u003e\n\u003ch2\u003eOutstanding Features\u003c\/h2\u003e\n\n\u003ctable class=\"tpl-features-table\"\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 150 KVA \/ 288.6 A\u003c\/span\u003e\u003cbr\u003emedium commercial with severe grid issues\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Individual phase control\u003c\/span\u003e\u003cbr\u003etelecom unbalanced loads OK\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ ±30% input range\u003c\/span\u003e\u003cbr\u003eextra tolerance for unstable grids\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Correction speed 20ms\/volt\u003c\/span\u003e\u003cbr\u003ebelow perception threshold\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 515mm cabinet\u003c\/span\u003e\u003cbr\u003ecolumnar regulator high-density design\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ GPRS + Modbus\u003c\/span\u003e\u003cbr\u003eremote monitoring (NOC \/ BMS)\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Chronically unstable grid\u003c\/span\u003e\u003cbr\u003esustained voltage dips handling\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ CE · UL · TÜV\u003c\/span\u003e\u003cbr\u003eengineering-grade compliance\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Zero harmonic distortion\u003c\/span\u003e\u003cbr\u003eclean power for IT \u0026amp; telecom loads\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable class=\"tpl-specs-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e150 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e288.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage tolerance\u003c\/td\u003e\n\u003ctd\u003e+30% to -30% (266V – 494V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% to ±1% (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrection speed\u003c\/td\u003e\n\u003ctd\u003e20 ms \/ volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad unbalance\u003c\/td\u003e\n\u003ctd\u003eUp to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation class\u003c\/td\u003e\n\u003ctd\u003eH Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP23 — Indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural Air + Forced Fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"TPL Stabilizers","offers":[{"title":"Default Title","offer_id":52015773942043,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/0255\/6699\/files\/3Ph.jpg?v=1775385772"},{"product_id":"tpl-series-three-phase-stabilizer-servo-liner-30-200kva","title":"TPL Series Three Phase Stabilizer Servo Liner 30% - 200KVA","description":"\u003cstyle\u003e\n\n\/* ==========================\n   TPL PRODUCT STYLE (200 KVA VERSION)\n========================== *\/\n\n.tpl-description{\n    font-family: inherit;\n    line-height:1.7;\n    color:#1f2937;\n}\n\n\/* ===== FEATURES GRID (CARDS) ===== *\/\n\n.tpl-features-table{\n    width:100%;\n    border-collapse:separate;\n    border-spacing:0 12px;\n    margin:30px 0;\n}\n\n.tpl-features-table td{\n    background:#EEF4FB;\n    border:1px solid rgba(0,82,157,.10);\n    border-radius:14px;\n    padding:16px;\n    vertical-align:top;\n    width:50%;\n}\n\n.tpl-features-table td p{\n    margin:0;\n    font-size:14px;\n    line-height:1.6;\n}\n\n.tpl-features-table td span{\n    font-weight:600;\n    color:#00529D;\n}\n\n\/* ===== SPEC TABLE ===== *\/\n\n.tpl-specs-table{\n    width:100%;\n    border-collapse:collapse;\n    border-radius:18px;\n    overflow:hidden;\n    margin-top:25px;\n}\n\n.tpl-specs-table thead th{\n    background:#00529D;\n    color:#fff;\n    padding:16px;\n    text-align:left;\n    font-size:15px;\n    font-weight:600;\n}\n\n.tpl-specs-table tbody tr:nth-child(odd){\n    background:#EEF4FB;\n}\n\n.tpl-specs-table tbody tr:nth-child(even){\n    background:#ffffff;\n}\n\n.tpl-specs-table td{\n    padding:14px;\n    border-bottom:1px solid rgba(0,82,157,.08);\n    font-size:14px;\n}\n\n.tpl-specs-table td:first-child{\n    font-weight:600;\n    color:#00529D;\n    width:35%;\n}\n\n.tpl-specs-table tr:hover{\n    background:rgba(0,82,157,.05);\n}\n\n\/* ===== MOBILE ===== *\/\n\n@media(max-width:768px){\n    .tpl-features-table td{\n        display:block;\n        width:100%;\n        margin-bottom:12px;\n    }\n}\n\n\u003c\/style\u003e\n\n\u003cdiv class=\"tpl-description\"\u003e\n\n\u003cp\u003e\nThe TPL 30% — 200 KVA at 433 A is designed for unstable shared grids affected by heavy industrial loads. Its ±30% input range (266V–494V) ensures stable operation under severe voltage fluctuations. Built with Class H insulation and \u0026gt;98% efficiency, it supports continuous industrial duty. With a weight of 1390 KG and dimensions of 515×1700×1127 mm, it is engineered for harsh environments.\n\u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003eOutstanding Features\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003ctable class=\"tpl-features-table\"\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 200 KVA \/ 433 A\u003c\/span\u003e\u003cbr\u003emedium industrial shared-grid protection\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ ±30% input range\u003c\/span\u003e\u003cbr\u003eabsorbs severe voltage dips\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 1390 KG build\u003c\/span\u003e\u003cbr\u003ecompact heavy-duty structure\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 100% load unbalance\u003c\/span\u003e\u003cbr\u003efull phase independence\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 266V–494V range\u003c\/span\u003e\u003cbr\u003ewidest operating window in class\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Internal bypass\u003c\/span\u003e\u003cbr\u003emaintenance without shutdown\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Class H insulation\u003c\/span\u003e\u003cbr\u003elong-term continuous operation\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Phase protection\u003c\/span\u003e\u003cbr\u003emotor safety assurance\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ \u0026gt;98% efficiency\u003c\/span\u003e\u003cbr\u003eenergy optimized performance\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Industrial applications\u003c\/span\u003e\u003cbr\u003eproduction \u0026amp; shared grid sites\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003ctable class=\"tpl-specs-table\"\u003e\n\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e200 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e433 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInput voltage tolerance\u003c\/td\u003e\n\u003ctd\u003e+30% to -30% (266V – 494V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCorrection speed\u003c\/td\u003e\n\u003ctd\u003e20 ms \/ volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInsulation class\u003c\/td\u003e\n\u003ctd\u003eH Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eProtection degree\u003c\/td\u003e\n\u003ctd\u003eIP23 — Indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"TPL Stabilizers","offers":[{"title":"Default Title","offer_id":52015784657179,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/0255\/6699\/files\/3Ph.jpg?v=1775385772"},{"product_id":"tpl-series-three-phase-stabilizer-servo-liner-30-1000kva","title":"TPL Series Three Phase Stabilizer Servo Liner 30% - 1000KVA","description":"\u003cstyle\u003e\n\n\/* ==========================\n   TPL PRODUCT STYLE (1000 KVA PREMIUM UI)\n========================== *\/\n\n.tpl-description{\n    font-family: inherit;\n    line-height:1.7;\n    color:#1f2937;\n}\n\n\/* ===== FEATURES GRID ===== *\/\n\n.tpl-features{\n    display:grid;\n    grid-template-columns:repeat(2,1fr);\n    gap:16px;\n    margin:30px 0;\n}\n\n.feature-item{\n    display:flex;\n    align-items:flex-start;\n    gap:14px;\n    background:#EEF4FB;\n    border:1px solid rgba(0,82,157,.10);\n    border-radius:18px;\n    padding:18px;\n    transition:.3s ease;\n}\n\n.feature-item:hover{\n    transform:translateY(-3px);\n    box-shadow:0 8px 24px rgba(0,82,157,.08);\n}\n\n.feature-icon{\n    width:42px;\n    height:42px;\n    min-width:42px;\n    border-radius:50%;\n    background:#00529D;\n    color:#fff;\n    display:flex;\n    align-items:center;\n    justify-content:center;\n    font-weight:700;\n    font-size:18px;\n}\n\n.feature-content strong{\n    display:block;\n    color:#00529D;\n    font-size:15px;\n    margin-bottom:6px;\n}\n\n.feature-content p{\n    margin:0;\n    color:#4b5563;\n    font-size:14px;\n    line-height:1.6;\n}\n\n\/* ===== SPEC TABLE ===== *\/\n\n.tpl-specs-table{\n    width:100%;\n    border-collapse:collapse;\n    overflow:hidden;\n    border-radius:18px;\n    margin-top:25px;\n}\n\n.tpl-specs-table thead th{\n    background:#00529D;\n    color:#fff;\n    padding:18px;\n    text-align:left;\n    font-size:15px;\n    font-weight:600;\n}\n\n.tpl-specs-table tbody tr:nth-child(odd){\n    background:#EEF4FB;\n}\n\n.tpl-specs-table tbody tr:nth-child(even){\n    background:#ffffff;\n}\n\n.tpl-specs-table td{\n    padding:18px;\n    border-bottom:1px solid rgba(0,82,157,.08);\n    color:#1f2937;\n    font-size:14px;\n}\n\n.tpl-specs-table td:first-child{\n    width:35%;\n    font-weight:600;\n    color:#00529D;\n}\n\n.tpl-specs-table tr:hover{\n    background:rgba(0,82,157,.04);\n}\n\n\/* ===== MOBILE ===== *\/\n\n@media(max-width:768px){\n    .tpl-features{\n        grid-template-columns:1fr;\n    }\n\n    .tpl-specs-table td,\n    .tpl-specs-table th{\n        padding:14px;\n    }\n}\n\n\u003c\/style\u003e\n\n\u003cdiv class=\"tpl-description\"\u003e\n\n\u003cp\u003e\nThe TPL 30% — 1000 KVA is a 1 MVA ±30% servo linear voltage stabilizer designed for mission-critical industrial infrastructure operating under severe and continuous grid instability. It delivers 1443.3 A of stable regulated output while maintaining precise 400V three-phase control even under extreme fluctuations. The system can withstand up to 34% voltage drops without tripping or waveform distortion. With a weight of 3505 KG and dimensions of 4020×2465×1400 mm, it is engineered as a long-term industrial power backbone.\n\u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003eOutstanding Features\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003cdiv class=\"tpl-features\"\u003e\n\n\u003cdiv class=\"feature-item\"\u003e\n\u003cdiv class=\"feature-icon\"\u003e✓\u003c\/div\u003e\n\u003cdiv class=\"feature-content\"\u003e\n\u003cstrong\u003e1000 KVA \/ 1 MVA\u003c\/strong\u003e\n\u003cp\u003eIndustrial-scale ±30% stabilization\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"feature-item\"\u003e\n\u003cdiv class=\"feature-icon\"\u003e✓\u003c\/div\u003e\n\u003cdiv class=\"feature-content\"\u003e\n\u003cstrong\u003e1443.3 A output\u003c\/strong\u003e\n\u003cp\u003eSupports heavy continuous loads\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"feature-item\"\u003e\n\u003cdiv class=\"feature-icon\"\u003e✓\u003c\/div\u003e\n\u003cdiv class=\"feature-content\"\u003e\n\u003cstrong\u003e34% voltage dip tolerance\u003c\/strong\u003e\n\u003cp\u003eNo shutdown under instability\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"feature-item\"\u003e\n\u003cdiv class=\"feature-icon\"\u003e✓\u003c\/div\u003e\n\u003cdiv class=\"feature-content\"\u003e\n\u003cstrong\u003e±30% input range\u003c\/strong\u003e\n\u003cp\u003e266V–494V extreme correction window\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"feature-item\"\u003e\n\u003cdiv class=\"feature-icon\"\u003e✓\u003c\/div\u003e\n\u003cdiv class=\"feature-content\"\u003e\n\u003cstrong\u003e3505 KG structure\u003c\/strong\u003e\n\u003cp\u003eHeavy-duty industrial design\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"feature-item\"\u003e\n\u003cdiv class=\"feature-icon\"\u003e✓\u003c\/div\u003e\n\u003cdiv class=\"feature-content\"\u003e\n\u003cstrong\u003e4020mm footprint\u003c\/strong\u003e\n\u003cp\u003eOptimized for plant integration\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"feature-item\"\u003e\n\u003cdiv class=\"feature-icon\"\u003e✓\u003c\/div\u003e\n\u003cdiv class=\"feature-content\"\u003e\n\u003cstrong\u003eZero harmonic distortion\u003c\/strong\u003e\n\u003cp\u003eClean regulated output power\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"feature-item\"\u003e\n\u003cdiv class=\"feature-icon\"\u003e✓\u003c\/div\u003e\n\u003cdiv class=\"feature-content\"\u003e\n\u003cstrong\u003eSmart monitoring\u003c\/strong\u003e\n\u003cp\u003eGPRS + Modbus integration ready\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"feature-item\"\u003e\n\u003cdiv class=\"feature-icon\"\u003e✓\u003c\/div\u003e\n\u003cdiv class=\"feature-content\"\u003e\n\u003cstrong\u003eEngineering support\u003c\/strong\u003e\n\u003cp\u003eFull design → commissioning\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003ctable class=\"tpl-specs-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e1000 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e1443.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInput voltage tolerance\u003c\/td\u003e\n\u003ctd\u003e+30% to -30% (266V – 494V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCorrection speed\u003c\/td\u003e\n\u003ctd\u003e20 ms \/ volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInsulation class\u003c\/td\u003e\n\u003ctd\u003eH Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eProtection degree\u003c\/td\u003e\n\u003ctd\u003eIP23 — Indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"TPL Stabilizers","offers":[{"title":"Default Title","offer_id":52015936995611,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/0255\/6699\/files\/TPL500.jpg?v=1775385772"},{"product_id":"tpl-series-three-phase-stabilizer-servo-liner-30-1500kva","title":"TPL Series Three Phase Stabilizer Servo Liner 30% - 1500KVA","description":"\u003cstyle\u003e\n\n\/* ==========================\n   TPL PRODUCT STYLE (1500 KVA VERSION)\n========================== *\/\n\n.tpl-description{\n    font-family: inherit;\n    line-height:1.7;\n    color:#1f2937;\n}\n\n\/* ===== FEATURES GRID ===== *\/\n\n.tpl-features-table{\n    width:100%;\n    border-collapse:separate;\n    border-spacing:0 12px;\n    margin:30px 0;\n}\n\n.tpl-features-table td{\n    background:#EEF4FB;\n    border:1px solid rgba(0,82,157,.10);\n    border-radius:14px;\n    padding:16px;\n    vertical-align:top;\n    width:50%;\n}\n\n.tpl-features-table td p{\n    margin:0;\n    font-size:14px;\n}\n\n.tpl-features-table td span{\n    font-weight:600;\n    color:#00529D;\n}\n\n\/* ===== SPEC TABLE ===== *\/\n\n.tpl-specs-table{\n    width:100%;\n    border-collapse:collapse;\n    border-radius:18px;\n    overflow:hidden;\n    margin-top:25px;\n}\n\n.tpl-specs-table thead th{\n    background:#00529D;\n    color:#fff;\n    padding:16px;\n    text-align:left;\n    font-size:15px;\n}\n\n.tpl-specs-table tbody tr:nth-child(odd){\n    background:#EEF4FB;\n}\n\n.tpl-specs-table tbody tr:nth-child(even){\n    background:#ffffff;\n}\n\n.tpl-specs-table td{\n    padding:14px;\n    border-bottom:1px solid rgba(0,82,157,.08);\n    font-size:14px;\n}\n\n.tpl-specs-table td:first-child{\n    font-weight:600;\n    color:#00529D;\n    width:35%;\n}\n\n.tpl-specs-table tr:hover{\n    background:rgba(0,82,157,.05);\n}\n\n\/* ===== MOBILE ===== *\/\n\n@media(max-width:768px){\n\n    .tpl-features-table td{\n        display:block;\n        width:100%;\n        margin-bottom:12px;\n    }\n\n}\n\n\u003c\/style\u003e\n\u003cdiv class=\"tpl-description\"\u003e\n\u003cp\u003eThe TPL 30% — 1500 KVA delivers 2165 A across a 6030mm multi-cabinet installation, providing centralized voltage regulation for high-demand facilities operating under severe grid instability. Designed for highly erratic input conditions, it ensures stable performance in mission-critical environments. Star Trans provides full project engineering support including load analysis, site surveys, installation planning, and commissioning. With a weight of 4180 KG and dimensions of 6030×2465×1400 mm, it is built for permanent large-scale industrial deployment.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eOutstanding Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable class=\"tpl-features-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ 1500 KVA \/ 2165 A\u003c\/span\u003e\u003cbr\u003e±30% extreme grid handling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ Output precision ±0.5%\u003c\/span\u003e\u003cbr\u003ehigh-accuracy voltage regulation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ 6030mm multi-cabinet\u003c\/span\u003e\u003cbr\u003ecentralized zone regulation system\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ Full engineering support\u003c\/span\u003e\u003cbr\u003edesign to commissioning\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ 4180 KG structure\u003c\/span\u003e\u003cbr\u003epermanent infrastructure unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ Load analysis included\u003c\/span\u003e\u003cbr\u003esite survey \u0026amp; installation planning\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ ±30% input range\u003c\/span\u003e\u003cbr\u003e266V–494V extreme stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ Smart integration\u003c\/span\u003e\u003cbr\u003eGPRS + Modbus connectivity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ Phase thermal isolation\u003c\/span\u003e\u003cbr\u003eindependent phase control\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cspan\u003e✔ Zero harmonic distortion\u003c\/span\u003e\u003cbr\u003eclean regulated output\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable class=\"tpl-specs-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e1500 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e2165 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage tolerance\u003c\/td\u003e\n\u003ctd\u003e+30% to -30% (266V – 494V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrection speed\u003c\/td\u003e\n\u003ctd\u003e20 ms \/ volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation class\u003c\/td\u003e\n\u003ctd\u003eH Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection degree\u003c\/td\u003e\n\u003ctd\u003eIP23 — Indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"TPL Stabilizers","offers":[{"title":"Default Title","offer_id":52015944696091,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/0255\/6699\/files\/TPL500.jpg?v=1775385772"},{"product_id":"tpl-series-three-phase-stabilizer-servo-liner-30-2000kva","title":"TPL Series Three Phase Stabilizer Servo Liner 30% - 2000KVA","description":"\u003cp\u003e\u003cstrong\u003eWhy Choose TPL Series?:\u003cbr\u003e\u003c\/strong\u003eCompensation for mains voltage fluctuations\u003cbr\u003eAssembly technology to lower heat losses\u003cbr\u003eBridging momentary voltage dips\u003cbr\u003eMay be switched between high control precision and elevated parasitic\u003cbr\u003eVoltage attenuation\u003cbr\u003eDisplay touch screen - show parameter\u003cbr\u003eProtection over\/under voltage - phase sequence -  phase failure - overload - short circuit - over heat - Internal bypass - safe start - I\/P MCCB\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eIdeal For:\u003c\/strong\u003e\u003cbr\u003eThree Phase Stabilizer Servo Liner securing the supply voltage in the event of mains overvoltage, mains undervoltage, voltage dips and voltage surges and in the case of brief voltage interruptions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eThree Phase Stabilizer Servo Liner\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eIEC 61000-4-48; IEC 61000-6-2; IEC 62103; IEC 60529\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eIEC 61558-2-14; IEC 61558-1\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"TPL Stabilizers","offers":[{"title":"Default Title","offer_id":52015970484507,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/0255\/6699\/files\/TPL500.jpg?v=1775385772"},{"product_id":"tpl-series-three-phase-stabilizer-servo-liner-30-2500kva","title":"TPL Series Three Phase Stabilizer Servo Liner 30% - 2500KVA","description":"\u003cstyle\u003e\n\n\/* ==========================\n   TPL PRODUCT STYLE (2000 KVA VERSION)\n========================== *\/\n\n.tpl-description{\n    font-family: inherit;\n    line-height:1.7;\n    color:#1f2937;\n}\n\n\/* ===== FEATURES GRID ===== *\/\n\n.tpl-features-table{\n    width:100%;\n    border-collapse:separate;\n    border-spacing:0 12px;\n    margin:30px 0;\n}\n\n.tpl-features-table td{\n    background:#EEF4FB;\n    border:1px solid rgba(0,82,157,.10);\n    border-radius:14px;\n    padding:16px;\n    vertical-align:top;\n    width:50%;\n}\n\n.tpl-features-table td p{\n    margin:0;\n    font-size:14px;\n}\n\n.tpl-features-table td span{\n    font-weight:600;\n    color:#00529D;\n}\n\n\/* ===== SPEC TABLE ===== *\/\n\n.tpl-specs-table{\n    width:100%;\n    border-collapse:collapse;\n    border-radius:18px;\n    overflow:hidden;\n    margin-top:25px;\n}\n\n.tpl-specs-table thead th{\n    background:#00529D;\n    color:#fff;\n    padding:16px;\n    text-align:left;\n    font-size:15px;\n}\n\n.tpl-specs-table tbody tr:nth-child(odd){\n    background:#EEF4FB;\n}\n\n.tpl-specs-table tbody tr:nth-child(even){\n    background:#ffffff;\n}\n\n.tpl-specs-table td{\n    padding:14px;\n    border-bottom:1px solid rgba(0,82,157,.08);\n    font-size:14px;\n}\n\n.tpl-specs-table td:first-child{\n    font-weight:600;\n    color:#00529D;\n    width:35%;\n}\n\n.tpl-specs-table tr:hover{\n    background:rgba(0,82,157,.05);\n}\n\n\/* ===== MOBILE ===== *\/\n\n@media(max-width:768px){\n\n    .tpl-features-table td{\n        display:block;\n        width:100%;\n        margin-bottom:12px;\n    }\n\n}\n\n\u003c\/style\u003e\n\n\u003cdiv class=\"tpl-description\"\u003e\n\n\u003cp\u003e\nThe TPL 30% — 2000 KVA is a 2 MVA installation delivering 2886.7 A with a ±30% input range, designed for major projects. Built as a 5997 KG unit with a 7370×2465×1400 mm footprint, it becomes a permanent part of the facility’s power infrastructure, protecting the entire downstream network from severe voltage events. It is delivered and commissioned by the full Star Trans engineering team.\n\u003c\/p\u003e\n\n\u003ch2\u003e\u003cstrong\u003eOutstanding Features\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003ctable class=\"tpl-features-table\"\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 2000 KVA \/ 2 MVA\u003c\/span\u003e\u003cbr\u003e±30% extreme scale stability\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ \u0026gt;98% efficiency\u003c\/span\u003e\u003cbr\u003emajor energy savings system\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 2886.7 A current\u003c\/span\u003e\u003cbr\u003efull network protection capability\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Phase independence\u003c\/span\u003e\u003cbr\u003ehandles load asymmetry\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 5997 KG system\u003c\/span\u003e\u003cbr\u003epermanent infrastructure unit\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ 7370mm footprint\u003c\/span\u003e\u003cbr\u003ecivil engineering coordination\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ ±30% input range\u003c\/span\u003e\u003cbr\u003e266V–494V extreme grid handling\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Certified system\u003c\/span\u003e\u003cbr\u003eCE · UL · TÜV compliance\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Zero harmonic distortion\u003c\/span\u003e\u003cbr\u003eclean 2 MVA output\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cspan\u003e✔ Full delivery service\u003c\/span\u003e\u003cbr\u003eengineering to commissioning\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/table\u003e\n\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003ctable class=\"tpl-specs-table\"\u003e\n\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e2000 KVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e400 Vac (Three Phase + Neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003e2886.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInput voltage tolerance\u003c\/td\u003e\n\u003ctd\u003e+30% to -30% (266V – 494V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eCorrection speed\u003c\/td\u003e\n\u003ctd\u003e20 ms \/ volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eInsulation class\u003c\/td\u003e\n\u003ctd\u003eH Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003eProtection degree\u003c\/td\u003e\n\u003ctd\u003eIP23 — Indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e","brand":"TPL Stabilizers","offers":[{"title":"Default Title","offer_id":52015972942107,"sku":null,"price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/0255\/6699\/files\/TPL500.jpg?v=1775385772"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/0255\/6699\/collections\/TPL500.jpg?v=1780551492","url":"https:\/\/startranseg.com\/en-eg\/collections\/30-tpl-stabilizers\/30-tpl.oembed","provider":"Star Trans","version":"1.0","type":"link"}