3-Phase Servo Linear Stabilizer – 100 kVA

SKU: TPL - 3 -30-100000

100 kVA 3-phase servo linear stabilizer (TPL Series 30%) with 3*400Vac+Neutral input/output, adjustable accuracy (0.5-1%), broad voltage tolerance (±30%), comprehensive protection, and advanced monitoring via touch screen

  • Description
  • Additional information

Description

is a 100 kVA three-phase servo linear voltage stabilizer from the TPL Series 30%, designed to maintain a stable output voltage even when the input voltage fluctuates significantly. It accepts a 3*400Vac+Neutral input and provides a regulated output with an adjustable accuracy of 0.5-1% across an input voltage tolerance of ±30%. This unit is equipped with extensive protection features, including over/under voltage, overload, short circuit, over heat, internal bypass, input circuit breaker, SafeStart, phase sequence, phase failure, and a ventilation system. Monitoring and control are performed through a user-friendly touch screen display that shows parameters like V, I, PF, and T, and allows for manual interference and fault record management. Communication is supported through Ethernet, USP, MODBUS TCP, and GPRS. With a high efficiency of >98% at full load, a 2-year warranty, and 25-year spare part availability, this robust stabilizer ensures reliable performance in demanding power environments. Optional enhancements include input/output surge arrestors, EMI/RFI filter, and a fire sensor. 🔧 Specifications:
• Reference No.: TPL – 3 – 30 – 100000
• Description: 3-Phase Servo Linear Stabilizer
• Model: TPL Series 30%
• Input Voltage (I/P): 3*400Vac + Neutral
• Output Voltage (O/P): 3*400Vac + Neutral
• Accuracy: 0.5-1% Adjustable
• Permissible Tolerance: ±30%
• Power: 100 kVA
• Current: 144.3A
• Frequency: 50Hz-60Hz ±5%
• Ambient Temperature: Up to 50°C
• Protection Degree: IP23
• Protections: Over/Under Voltage, Overload, Short Circuit, Over Heat, Internal Bypass, I/P Circuit Breaker, SafeStart, Phase Sequence, Phase Failure, Ventilation System
• Harmonic Distortion: Nil
• Insulation Class: H
• Insulated Strength: 2500V/min
• Cooling: Natural Air + Fans (Forced Ventilation)
• Admitted Load Variation: 0 to 100%
• Admitted Load Unbalance: Up to 100%
• Admitted Overload: 150% for 1 min
• Control Each Phase: Independent Phase Control
• Correction Time: 20ms/volt (for full regulation)
• Display & Instrumentation: Touch Screen (V,I,PF,T.), Manual Interference, Fault Record
• Communication System: Ethernet, USP, MODBUS TCP, GPRS
• Efficiency: >98% at full load
• Display: LCD Display
• Warranty: 2 years
• Maintenance: Spare parts exist for 25 years
• Weight: 830 kg
• Dimensions: 407 × 1650 × 930 mm
• Option: Input/Output Surge Arrestor (Class I/II), EMI/RFI Filter, Fire Sensor
• IEC Standards: IEC-61558-48, IEC 61000-6-2, IEC 62103, IEC 60529, IEC 61558-2 & IEC 61558-1 💡 Applications:
• Industrial automation systems requiring stable power with fluctuating mains
• Commercial complexes in areas with unreliable power grids
• Sensitive electronic equipment needing protection from a wide range of voltage variations
• Ensuring consistent power supply for critical loads in challenging electrical environments

Download data sheet

Additional information

referance no

TPL – 3 -30-100000

description

3ph phase stabilizer – Servo Linear

model

TPL Seies 30%

I/P

3*400Vac+ Neutral

O/P

3*400Vac+ Neutral

accuracy

0.5-1% adjustable

premissible tolarance in volt

30% up-30% down

Power

100KVA

Current

144.3A

Frequency

50HZ-60HZ ±5%

Ambient temprature

50C

protection degree

IP23

Protection

"OVER VOLTAGE – UNDER VOLTAGE – OVERLOAD
SHORT CIRCUIT – OVER HEAT – Internal BYPASS-I/P Circuit breaker Safestart-phase sequance – phase failure – ventlation system"

harmonic destortion

nill

insulation class

H

Insulated strength

2500V/ min

cooling

Natural Air+ Fans (Provided forced ventlation )

Adimatted load variation

0 to 100%

Adimatted load unbalance

up to 100%

Adimatted overload

150% for 1 min

control each phase

indepandent phase control

correction time for full regulation

20ms/volt

Display& Instrumentation

Touch Screen – show Parameter (V,I,PF,T.) Man Interference – Fault Record

Communication System

Ethernet – USP- MODBUS TCP-GPRS

efficiency

>98% at full load

Display

LCD Display

warranty

2 years

maintainance

spare part exsist for 25 years

weight

830KG

dim

407*1650*930

option

Input Surge Areesstor Class I or output Surge
Areesstor Class II – EMI/RFI Filter & Fire sensor

Standared IEC

IEC -61558-48 , IEC 61000-6-2 , IEC 62103 ,
IEC 60529 , IEC 61558-2 & IEC 61558-1