3-Phase Servo Linear Stabilizer – 300 kVA

SKU: TPL - 3 -30-300000

300 kVA 3-phase servo linear stabilizer (TPL Series 30%) with 3*400Vac+Neutral input/output, adjustable accuracy (0.5-1%), wide input voltage tolerance (±30%), comprehensive protection, and intelligent touch screen interface

  • Description
  • Additional information

Description

is a high-capacity 300 kVA three-phase servo linear voltage stabilizer from the TPL Series 30%, designed to provide stable and precise power output even under substantial input voltage fluctuations. It accepts a 3*400Vac+Neutral input and delivers a regulated output with an adjustable accuracy of 0.5-1% across an input voltage tolerance of ±30%. This unit is equipped with a full suite of protection features, including over/under voltage, overload, short circuit, over heat, internal bypass, input circuit breaker, SafeStart, phase sequence, phase failure, and a ventilation system. An intelligent touch screen allows for monitoring of parameters such as V, I, PF, and T, and offers manual interference and fault record capabilities. Communication is supported via Ethernet, USP, MODBUS TCP, and GPRS. With a high efficiency of >98% at full load, a 2-year warranty, and 25-year spare part availability, this robust stabilizer ensures reliable long-term performance for large-scale operations in challenging power environments. Optional enhancements include input/output surge arrestors, EMI/RFI filter, and a fire sensor. 🔧 Specifications:
• Reference No.: TPL – 3 – 30 – 300000
• Description: 3-Phase Servo Linear Stabilizer
• Model: TPL Series 30%
• Input Voltage (I/P): 3*400Vac + Neutral
• Output Voltage (O/P): 3*400Vac + Neutral
• Accuracy: 0.5-1% Adjustable
• Permissible Tolerance: ±30%
• Power: 300 kVA
• Current: 577.35A
• Frequency: 50Hz-60Hz ±5%
• Ambient Temperature: Up to 50°C
• Protection Degree: IP23
• Protections: Over/Under Voltage, Overload, Short Circuit, Over Heat, Internal Bypass, I/P Circuit Breaker, SafeStart, Phase Sequence, Phase Failure, Ventilation System
• Harmonic Distortion: Nil
• Insulation Class: H
• Insulated Strength: 2500V/min
• Cooling: Natural Air + Fans (Forced Ventilation)
• Admitted Load Variation: 0 to 100%
• Admitted Load Unbalance: Up to 100%
• Admitted Overload: 150% for 1 min
• Control Each Phase: Independent Phase Control
• Correction Time: 20ms/volt (for full regulation)
• Display & Instrumentation: Touch Screen (V,I,PF,T.), Manual Interference, Fault Record
• Communication System: Ethernet, USP, MODBUS TCP, GPRS
• Efficiency: >98% at full load
• Display: LCD Display
• Warranty: 2 years
• Maintenance: Spare parts exist for 25 years
• Weight: 1705 kg
• Dimensions: 2010 × 2320 × 1400 mm
• Option: Input/Output Surge Arrestor (Class I/II), EMI/RFI Filter, Fire Sensor
• IEC Standards: IEC-61558-48, IEC 61000-6-2, IEC 62103, IEC 60529, IEC 61558-2 & IEC 61558-1 💡 Applications:
• Large industrial facilities operating under significant power supply variations
• Major commercial complexes in regions with unstable or unreliable power infrastructure
• Critical electronic systems requiring highly stable power across a broad input voltage range
• Ensuring consistent and protected power for large-scale operations in challenging electrical environments

Download data sheet

Additional information

referance no

TPL – 3 -30-300000

description

3ph phase stabilizer – Servo Linear

model

TPL Seies 30%

I/P

3*400Vac+ Neutral

O/P

3*400Vac+ Neutral

accuracy

0.5-1% adjustable

premissible tolarance in volt

30% up-30% down

Power

300KVA

Current

577.35

Frequency

50HZ-60HZ ±5%

Ambient temprature

50C

protection degree

IP23

Protection

OVER VOLTAGE – UNDER VOLTAGE – OVERLOAD
SHORT CIRCUIT – OVER HEAT – Internal BYPASS-I/P Circuit breaker Safestart-phase sequance – phase failure – ventlation system

harmonic destortion

nill

insulation class

H

Insulated strength

2500V/ min

cooling

Natural Air+ Fans (Provided forced ventlation )

Adimatted load variation

0 to 100%

Adimatted load unbalance

up to 100%

Adimatted overload

150% for 1 min

control each phase

indepandent phase control

correction time for full regulation

20ms/volt

Display& Instrumentation

Touch Screen – show Parameter (V,I,PF,T.) Man Interference – Fault Record

Communication System

Ethernet – USP- MODBUS TCP-GPRS

efficiency

>98% at full load

Display

LCD Display

warranty

2 years

maintainance

spare part exsist for 25 years

weight

1705KG

dim

2010*2320*1400

option

Input Surge Areesstor Class I or output Surge
Areesstor Class II – EMI/RFI Filter & Fire sensor

Standared IEC

IEC -61558-48 , IEC 61000-6-2 , IEC 62103 ,
IEC 60529 , IEC 61558-2 & IEC 61558-1