3-Phase Servo Linear Stabilizer – 500 kVA

SKU: TPL - 3 -30-500000

500 kVA 3-phase servo linear stabilizer (TPL Series 30%) with 3*400Vac+Neutral input/output, adjustable accuracy (0.5-1%), wide input voltage tolerance (±30%), comprehensive protection, and sophisticated touch screen control

  • Description
  • Additional information

Description

three-phase servo linear voltage stabilizer from the TPL Series 30%, designed for demanding industrial and commercial applications requiring stable and precise power even with substantial input voltage variations. It accepts a 3*400Vac+Neutral input and delivers a regulated output with an adjustable accuracy of 0.5-1% across an input voltage tolerance of ±30%. This unit incorporates an exhaustive array of protection features, including over/under voltage, overload, short circuit, over heat, internal bypass, input circuit breaker, SafeStart, phase sequence, phase failure, and a high-efficiency ventilation system. A sophisticated touch screen interface provides detailed real-time monitoring of crucial parameters (V, I, PF, T), advanced manual intervention capabilities, and comprehensive fault history management. Seamless communication is ensured through Ethernet, USP, MODBUS TCP, and GPRS integration. With a high efficiency exceeding 98% at full load, backed by a 2-year warranty and long-term spare part support, this robust stabilizer guarantees unwavering and dependable power for critical infrastructure and large industrial complexes in challenging power environments. Premium optional features include high-grade input/output surge arrestors, enhanced EMI/RFI filtering, and an integrated fire detection and suppression system. 🔧 Specifications:
• Reference No.: TPL – 3 – 30 – 500000
• Description: 3-Phase Servo Linear Stabilizer
• Model: TPL Series 30%
• Input Voltage (I/P): 3*400Vac + Neutral
• Output Voltage (O/P): 3*400Vac + Neutral
• Accuracy: 0.5-1% Adjustable
• Permissible Tolerance: ±30%
• Power: 500 kVA
• Current: 721.68A
• Frequency: 50Hz-60Hz ±5%
• Ambient Temperature: Up to 50°C
• Protection Degree: IP23
• Protections: Over/Under Voltage, Overload, Short Circuit, Over Heat, Internal Bypass, I/P Circuit Breaker, SafeStart, Phase Sequence, Phase Failure, Ventilation System
• Harmonic Distortion: Nil
• Insulation Class: H
• Insulated Strength: 2500V/min
• Cooling: Natural Air + Fans (Forced Ventilation)
• Admitted Load Variation: 0 to 100%
• Admitted Load Unbalance: Up to 100%
• Admitted Overload: 150% for 1 min
• Control Each Phase: Independent Phase Control
• Correction Time: 20ms/volt (for full regulation)
• Display & Instrumentation: Touch Screen (V,I,PF,T.), Manual Interference, Fault Record
• Communication System: Ethernet, USP, MODBUS TCP, GPRS
• Efficiency: >98% at full load
• Display: LCD Display
• Warranty: 2 years
• Maintenance: Spare parts exist for 25 years
• Weight: 1905 kg
• Dimensions: 2010 × 2320 × 1400 mm
• Option: Input/Output Surge Arrestor (Class I/II), EMI/RFI Filter, Fire Sensor
• IEC Standards: IEC-61558-48, IEC 61000-6-2, IEC 62103, IEC 60529, IEC 61558-2 & IEC 61558-1 💡 Applications:
• Large industrial facilities and heavy-duty machinery operating under significant power supply variations
• Major commercial complexes and critical infrastructure in regions with unstable power grids
• Critical electronic systems requiring highly stable power across a broad input voltage range
• Ensuring consistent and protected power for large-scale operations in challenging electrical environments

Download data sheet

Additional information

referance no

TPL – 3 -30-500000

description

3ph phase stabilizer – Servo Linear

O/P

3*400Vac+ Neutral

accuracy

0.5-1% adjustable

premissible tolarance in volt

30% up-30% down

Power

500KVA

Current

721.68A

Protection

OVER VOLTAGE – UNDER VOLTAGE – OVERLOAD
SHORT CIRCUIT – OVER HEAT – Internal BYPASS-I/P Circuit breaker Safestart-phase sequance – phase failure – ventlation system

harmonic destortion

nill

insulation class

H

Insulated strength

2500V/min

cooling

Natural Air+ Fans (Provided forced ventlation )

Adimatted load unbalance

up to 100%

Adimatted overload

150% for 1 min

control each phase

indepandent phase control

correction time for full regulation

20ms/volt

Display& Instrumentation

Touch Screen – show Parameter (V,I,PF,T.) Man Interference – Fault Record

Communication System

Ethernet – USP- MODBUS TCP-GPRS

efficiency

>98% at full load

Display

LCD Display

warranty

2 years

maintainance

spare part exsist for 25 years

weight

1905KG

dim

2010*2320*1400

option

Input Surge Areesstor Class I or output Surge
Areesstor Class II – EMI/RFI Filter & Fire sensor

Standared IEC

IEC -61558-48 , IEC 61000-6-2 , IEC 62103 ,
IEC 60529 , IEC 61558-2 & IEC 61558-1