3-Phase Servo Linear Stabilizer – 500 kVA

SKU: TPL - 3 -20-500000

500 kVA 3-phase servo linear stabilizer (TPL Series 20%) with 3*400Vac+Neutral input/output, adjustable accuracy (0.5-1%), wide tolerance (±20%), comprehensive protection, and sophisticated touch screen control.

  • Description
  • Additional information

Description

the pinnacle of three-phase servo linear voltage stabilization, offering a substantial 500 kVA capacity from the TPL Series 20%. Designed for the most demanding industrial and utility-scale applications, it accepts a 3*400Vac+Neutral input and delivers an exceptionally stable output with an adjustable accuracy of 0.5-1%, even amidst significant input voltage variations of ±20%. This unit incorporates an exhaustive array of protection features, including over/under voltage, overload, short circuit, over heat, internal bypass, input circuit breaker, SafeStart, phase sequence, phase failure, and a high-efficiency ventilation system. A sophisticated touch screen interface provides detailed real-time monitoring of crucial parameters (V, I, PF, T), advanced manual intervention capabilities, and comprehensive fault history management. Seamless communication is ensured through Ethernet, USP, MODBUS TCP, and GPRS integration. With a high efficiency exceeding 98% at full load, backed by a 2-year warranty and long-term spare part support, this robust stabilizer guarantees unwavering and dependable power for critical infrastructure and large industrial complexes. Premium optional features include high-grade input/output surge arrestors, enhanced EMI/RFI filtering, and an integrated fire detection and suppression system. 🔧 Specifications:
• Reference No.: TPL – 3 – 20 – 500000
• Description: 3-Phase Servo Linear Stabilizer
• Model: TPL Series 20%
• Input Voltage (I/P): 3*400Vac + Neutral
• Output Voltage (O/P): 3*400Vac + Neutral
• Accuracy: 0.5-1% Adjustable
• Permissible Tolerance: ±20%
• Power: 500 kVA
• Current: 721.68A
• Frequency: 50Hz-60Hz ±5%
• Ambient Temperature: Up to 50°C
• Protection Degree: IP23
• Protections: Over/Under Voltage, Overload, Short Circuit, Over Heat, Internal Bypass, I/P Circuit Breaker, SafeStart, Phase Sequence, Phase Failure, Ventilation System
• Harmonic Distortion: Nil
• Insulation Class: H
• Insulated Strength: 2500V/min
• Cooling: Natural Air + Fans (Forced Ventilation)
• Admitted Load Variation: 0 to 100%
• Admitted Load Unbalance: Up to 100%
• Admitted Overload: 150% for 1 min
• Control Each Phase: Independent Phase Control
• Correction Time: 20ms/volt (for full regulation)
• Display & Instrumentation: Touch Screen (V,I,PF,T.), Manual Interference, Fault Record
• Communication System: Ethernet, USP, MODBUS TCP, GPRS
• Efficiency: >98% at full load
• Display: LCD Display
• Warranty: 2 years
• Maintenance: Spare parts exist for 25 years
• Weight: 1709 kg
• Dimensions: 2010 × 2320 × 1400 mm
• Option: Input/Output Surge Arrestor (Class I/II), EMI/RFI Filter, Fire Sensor
• IEC Standards: IEC-61558-48, IEC 61000-6-2, IEC 62103, IEC 60529, IEC 61558-2 & IEC 61558-1 💡 Applications:
• Utility-scale power stabilization and conditioning for grid-connected systems
• Extremely large industrial complexes with highly sensitive and critical equipment
• Major infrastructure projects such as airports, transportation networks, and large data centers
• Environments with severe power quality challenges requiring advanced control, monitoring, and redundancy

Download data sheet

Additional information

referance no

TPL – 3 -20-500000

description

3ph phase stabilizer – Servo Linear

I/P

3*400Vac+ Neutral

accuracy

0.5-1% adjustable

premissible tolarance in volt

20% up-20% down

Power

500KVA

Current

721.68A

ambient Temprature

50C

protection degree

IP23

protection

"OVER VOLTAGE – UNDER VOLTAGE – OVERLOAD
SHORT CIRCUIT – OVER HEAT – Internal BYPASS-I/P Circuit breaker Safestart-phase sequance – phase failure – ventlation system"

harmonic destortion

nill

insulation class

H

Insulated strength

2500V/ min

cooling

Natural Air+ Fans (Provided forced ventlation )

Adimatted load variation

0 to 100%

Adimatted load unbalance

up to 100%

Adimatted overload

150% for 1 min

control each phase

indepandent phase control

correction time for full regulation

20ms/volt

Display& Instrumentation

Touch Screen – show Parameter (V,I,PF,T.) Man Interference – Fault Record

Communication System

Ethernet – USP- MODBUS TCP-GPRS

display

LCD Display

warranty

2 years

maintainance

spare part exsist for 25 years

weight

1709kg

dim

2010*2320*1400

Standared IEC

IEC -61558-48 , IEC 61000-6-2 , IEC 62103 ,
IEC 60529 , IEC 61558-2 & IEC 61558-1