800 kVA 3-phase servo linear stabilizer (TPL Series 20%) with 3*400Vac+Neutral input/output, adjustable accuracy (0.5-1%), wide tolerance (±20%), comprehensive protection, and advanced communication and safety features
- Description
- Additional information
Description
is a very high-capacity 800 kVA three-phase servo linear voltage stabilizer from the TPL Series 20%, designed for the most demanding utility-scale and mega-industrial applications requiring ultimate power stability, control, and safety. It accepts a 3*400Vac+Neutral input and provides an exceptionally stable output with an adjustable accuracy of 0.5-1%, even under severe input voltage variations of ±20%. This unit incorporates a comprehensive suite of protection mechanisms, including over/under voltage, overload, short circuit, over heat, internal bypass, input circuit breaker, SafeStart, phase sequence, phase failure, and a high-efficiency, redundant ventilation system. An advanced touch screen interface offers detailed real-time monitoring of all critical parameters (V, I, PF, T), sophisticated manual intervention capabilities, and extensive fault history management. Seamless integration with complex power management systems is ensured through Ethernet, USP, MODBUS TCP, and GPRS communication protocols. With a high efficiency exceeding 98% at full load, a 2-year warranty, and long-term spare part support, this robust stabilizer guarantees unwavering and dependable power for the most critical infrastructure and mega-industrial complexes. Premium optional features include high-grade input/output surge arrestors (Class I/II), advanced EMI/RFI filtering, and a comprehensive, integrated fire detection and suppression system. 🔧 Specifications:
• Reference No.: TPL – 3 – 20 – 800000
• Description: 3-Phase Servo Linear Stabilizer
• Model: TPL Series 20%
• Input Voltage (I/P): 3*400Vac + Neutral
• Output Voltage (O/P): 3*400Vac + Neutral
• Accuracy: 0.5-1% Adjustable
• Permissible Tolerance: ±20%
• Power: 800 kVA
• Current: 1154.7A
• Frequency: 50Hz-60Hz ±5%
• Ambient Temperature: Up to 50°C
• Protection Degree: IP23
• Protections: Over/Under Voltage, Overload, Short Circuit, Over Heat, Internal Bypass, I/P Circuit Breaker, SafeStart, Phase Sequence, Phase Failure, Ventilation System
• Harmonic Distortion: Nil
• Insulation Class: H
• Insulated Strength: 2500V/min
• Cooling: Natural Air + Fans (Forced Ventilation)
• Admitted Load Variation: 0 to 100%
• Admitted Load Unbalance: Up to 100%
• Admitted Overload: 150% for 1 min
• Control Each Phase: Independent Phase Control
• Correction Time: 20ms/volt (for full regulation)
• Display & Instrumentation: Touch Screen (V,I,PF,T.), Manual Interference, Fault Record
• Communication System: Ethernet, USP, MODBUS TCP, GPRS
• Efficiency: >98% at full load
• Display: LCD Display
• Warranty: 2 years
• Maintenance: Spare parts exist for 25 years
• Weight: 2404 kg
• Dimensions: 2010 × 2320 × 1400 mm
• Option: Input/Output Surge Arrestor (Class I/II), EMI/RFI Filter, Fire Sensor
• IEC Standards: IEC-61558-48, IEC 61000-6-2, IEC 62103, IEC 60529, IEC 61558-2 & IEC 61558-1 💡 Applications:
• Utility-scale power grid stabilization and conditioning for large metropolitan areas
• Mega-industrial complexes, heavy resource extraction, and critical national infrastructure
• Major international airports, transportation hubs, and ultra-large data centers
• Environments with extreme power quality challenges requiring the highest levels of control, monitoring, safety, and redundancy
Additional information
referance no | TPL – 3 -20-800000 |
---|---|
description | 3ph phase stabilizer – Servo Linear |
model | TPL Seies 20% |
I/P | 3*400Vac+ Neutral |
accuracy | 0.5-1% adjustable |
premissible tolarance in volt | 20% up-20% down |
Power | 800KVA |
Current | 1154.7A |
Frequency | 50HZ-60HZ ±5% |
Ambient temprature | 50C |
protection degree | IP23 |
Protection | "OVER VOLTAGE – UNDER VOLTAGE – OVERLOAD |
harmonic destortion | nill |
insulation class | H |
Insulated strength | 2500V/ min |
cooling | Natural Air+ Fans (Provided forced ventlation ) |
Adimatted load variation | 0 to 100% |
Adimatted load unbalance | up to 100% |
Adimatted overload | 150% for 1 min |
control each phase | indepandent phase control |
correction time for full regulation | 20ms/volt |
Display& Instrumentation | Touch Screen – show Parameter (V,I,PF,T.) Man |
Communication System | Ethernet – USP- MODBUS TCP-GPRS |
efficiency | >98% at full load |
Display | LCD Display |
warranty | 2 years |
maintainance | spare part exsist for 25 years |
weight | 2404kg |
dim | 2010*2320*1400 |
option | Input Surge Areesstor Class I or output Surge |
Standared IEC | IEC -61558-48 , IEC 61000-6-2 , IEC 62103 , |